Products​

Vortex flow meter​

The LUGB series vortex flowmeter is a new type of flowmeter introduced by our company, featuring a reasonable design, powerful functions, and leading-edge linear correction capabilities. It utilizes a sophisticated, low-power 45×30 full-dot matrix LCD display for clear and intuitive operation. RS485 or HART communication options meet various user needs, and multiple compensation algorithms can satisfy almost all flow compensation calculations.

Describe

Working principle​

The basic principle of the intelligent vortex flowmeter is the Kármán vortex street principle, which states that “the vortex shedding frequency is proportional to the flow velocity.” The diameter of the flowmeter’s main body is essentially the same as the instrument’s nominal diameter. As shown in Figure 1, a roughly isosceles triangular prism is inserted into the flow body. The axis of the prism is perpendicular to the direction of the measured medium’s flow, with its base facing the fluid. When the measured medium flows past the prism, vortices are alternately generated on both sides of the prism. These vortices are continuously generated and shed, forming two staggered rows of vortices downstream of the prism, known as the “vortex street.” Theoretical analysis and experiments have proven that the vortex shedding frequency is directly proportional to the fluid velocity on the sides of the prism.

Features​

▲ Non-blocking design: The entire sensor and wetted parts are made of stainless steel, with a simple structure and no moving parts, minimizing the risk of failure due to holes, gaps, and gaskets.

▲ Mechanical vibration resistance: The company has optimized the circuit design to effectively filter out vibration frequencies caused by mechanical vibrations.

▲ Simplified troubleshooting: The sensor is isolated from the process, ensuring easy installation, constant instrument coefficients, high data repeatability, good compatibility between the converter and the sensor, and convenient and quick maintenance.

▲ System stability: The detection sensor does not directly contact the measured medium, and features water hammer and lightning protection designs. The housing is corrosion-resistant and dirt-resistant; long-term system testing has proven its stable performance, long service life, high temperature resistance, and high reliability.

▲ Analog and digital signal processing: The converter adopts advanced circuit design, allowing for both manual analog settings and adaptive digital processing. It features no zero-point drift, high accuracy, a wide measurement range, a typical range ratio of 10:1, and a maximum of 15:1.

Main technical parameters​

Nominal diameter15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300…
Pressure LevelPN16 (larger than PN16, order by agreement)
Medium and temperatureMedium: liquid, gas, steam, thermal oil; temperature: -20~250℃; -20~350℃
Body materialSS304; SS316L agreement ordering
Allow vibration acceleration0.2g
AccuracyLevel 1.0; Level 1.5; Level 2.5
Turn down1:6; 1:10; 1:15
Supply voltage3.6V battery; DC24V
Output signalPulse, 4~20mA, RS485, Hart protocol
Explosion-proof signsExdII CT6 Gb
Protection levelIP65;IP68 protocol ordering
Environmental
conditions
-20~55℃; relative humidity: 5~95%; atmospheric pressure:
86~106Kpa
ShowNo display; LCD display
Electrical InterfaceM20X1.5;NPT1/2

Instrument Structure and Installation Dimensions ​

Ordinary clamping size

Ordinary body
Nominal diameterLong LOuter diameter DTotal high H
15806 3364
20806 3364
25806 3364
32806 3364
408078384
508078384
6580100404
80100113427
100100132436
125100158479
150110180506
200140240589
250160298615
300180350666

Ordinary flange connection dimensions

Ordinary flange connection body
Nominal diameterLDHKn*φ
1520095381654*14
20200105386754*14
25200115391854*14
322001404041004*18
402001504191104*18
502001654261254*18
652001854461454*18
802002004651608*18
1002002204711808*18
1252502504992108*18
1503002855302408*22
20030034058329512*22
25030040564335012*22
30030046069540012*22

Flow rate range table by pipe diameter​

Flow rate range(m³/h)

Nominal diameterDN(mm)

liquid

gas

15

0.6~6

3~12

20

1~10

5~30

25

1.6~16

8~70

32

2.2~20

15~150

40

2.5~25

20~200

50

3.5~35

35~350

65

6.5~68

50~500

80

10~100

70~700

100

15~150

110~1500

125

27~275

150~1500

150

40~400

250~2200

200

80~800

600~4000

250

120~1200

960~5500

300

180~1800

1500~11500

FAQ

We provide you with the advantages of a reliable manufacturer.

Are you the source factory?

Yes. We are a professional manufacturer of flow meters and Industrial instrument, production, sales, and service. With excellent processing equipment and advanced technology, we have received multiple honors and customer praise.

We have products like oval gear flow meter, turbine flow meter, electromagnetic flow meter, vortex flow meter, mass flow meter, ultrasonic flow meter, radar level meter, precession vortex flow meter, etc.

Standard one year warranty, and lifetime technical support is provided for all our client.  

All the flow meter and sensor have passed the national quality inspection and obtained ISO certification for quality management system certification, CE certificate, high-tech enterprise certificate, calibration certificate and all the products will be verified as qualified before shipment.

Standard: 1-2 working days shipment
Custom models or in bulk: negotiate the specific time

Sure thing, we’ll provide English manual and tutorials for you. For all our client, And our technical engineers are always at your service!

Contact Us

Scroll to Top